To the editor:
In the past August issue of the ASHI Reporter, there was an article titled “What is Spray polyurethane foam?” from the Spray Polyurethane Foam Alliance.
I find it rather odd this rather informative article includes no mention whatsoever regarding ultraviolet degradation. The article does address SPF roof system maintenance and mentions re-coating, but no reference is made to the fact that a primary reason for the re-coating is to protect the SPF from ultraviolet radiation. SPF roof coatings frequently consist of an aluminum-fibered coating specifically applied to help prevent ultraviolet degradation.
I doubt there’s a home inspector among us who hasn’t knowingly or otherwise observed such degradation: For example, when SPF is used in lieu of plumber’s putty to seal where HVAC and/or electric service lines enter structures. Initially, the surface of SPF, when applied, exhibits a smooth, light tan or beige skin-like surface. When unprotected from ultraviolet, the color darkens, the skin disappears and a dark orange, porous, sponge-like surface appears.
Mark S. Londner, AIA, ASHI Certified InspectorLBI Home Inspection
Purcellville, Va.
Edited by ASHI Staff
ASHI’s Web site, www.ashi.org, is the definitive resource for inspectors, consumers, real estate professionals and the media for information, advice and resources dedicated to home inspection. Here you’ll find a wealth of shared ASHI home inspection knowledge at your disposal. Your feedback and comments are welcome.